• Reading time:8 mins read
  • Post category:Uncategorized
FontanaShowers® AEC Technical Resource

Fontana BIM, Revit & Faucet Specification Resource

A specification-focused reference for architects, plumbing engineers, BIM coordinators, contractors and facility teams working with FontanaShowers® commercial touchless faucets. Use this page to coordinate model numbers, fixture geometry, mounting conditions, deck openings, plumbing connections, control-box locations, sensor clearances and current BIM/Revit documentation before issuing construction documents.

Specification coordination: BIM geometry should be coordinated with the current product page, installation document and approved project submittal. Dimensions shown below are nominal manufacturer data. Verify the actual fixture, basin, countertop thickness, power configuration and plumbing conditions before drilling, fabrication or final rough-in.

BIM / Revit Files and Digital Coordination Formats

Use the current Fontana BIM library to obtain the available digital object for the selected SKU and project software version.

RFA

Native Revit family format for placement, scheduling, parameter coordination and project modeling.

IFC

Interoperable BIM exchange format for multidisciplinary coordination outside native Revit workflows.

DWG

CAD geometry for plans, elevations, details and conventional architectural or plumbing coordination.

PDF / Cut Sheet

Manufacturer dimensional and installation documentation for submittals, rough-in review and field verification.

Fontana Touchless Faucet BIM / Specification Schedule

Product IDs and coordination data intended for architectural, plumbing and BIM fixture schedules.

Product ID Mounting Published Dimensions Rough-In / Connection Coordination
FB085BN
Arden MotionPlus™
Deck mounted Available approximately 6.9 in, 9.23 in and larger configuration. Deck opening 32–35 mm.
Maximum counter thickness: 35 mm.
G1/2 inlet / outlet.
Control box approximately 5 × 4.7 in. Maintain under-basin access for sensor cable, hose and valve servicing.
FS-9539B
Bravat Commercial Sensor Faucet
Deck mounted Overall height: 10 in.
Spout projection: 6.2 in.
Outlet height: 6 in.
Body diameter: approximately 2 in.
Mounting opening: 33–35 mm.
G1/2 inlet / outlet.
Sensor zone: 16–32 cm adjustable.
Maximum countertop thickness shown as 35 mm. Control box approximately 5 × 4.7 in.
FS8033CH
AquaDynamiCore™ Chrome
Single-hole deck mounted Overall height: 4.61 in.
Width: 2.36 in.
Spout height: 3.54 in.
Spout reach: 5.87 in.
Spout length: 7.48 in.
Coordinate single-hole faucet mounting, hot/cold supply and electrical / sensor components with selected basin. Stream position should be checked against bowl depth, drain centerline and backsplash.
FS75114BG
Bonifacio Brushed Gold
Single-hole deck mounted Overall height: 8.58 in.
Width: 2.20 in.
Spout reach: 7.20 in.
Spout height: 7.68 in.
One-hole installation. Coordinate hot/cold supply and electrical connector below the lavatory. Verify the 7.20 in projection against the selected basin before countertop release.
FS10003CP
FlowSphere™ Champagne
Wall mounted Wall installation geometry to be coordinated from current BIM / approved submittal. G1/2 inlet.
G1/2 outlet.
AC/DC power.
Coordinate finished-wall depth, outlet projection, basin centerline, sensor field and service access.
Fontana FB085BN brushed nickel commercial touchless faucet BIM specification and deck mounting reference
PRODUCT ID: FB085BN

Fontana Arden MotionPlus™ Brushed Nickel Touchless Faucet

Deck Mount Commercial AC / DC Adjustable Sensor
Mounting Opening 32–35 mm
Maximum Counter Thickness 35 mm / 1.38 in
Water Connection G1/2 inlet / outlet
Control Box Approx. 5 × 4.7 in
Water Pressure 0.05–1.2 MPa
Aerator Options 0.5–1.5 GPM

Coordinate the threaded faucet shank with countertop construction, undermount basin flange and structural support. The control box, sensor cable, water hose and optional mixing components require accessible space below the lavatory.

Bravat FS-9539B brushed nickel commercial sensor faucet dimensional BIM and rough-in reference
PRODUCT ID: FS-9539B

Bravat Brushed Nickel Commercial Sensor Faucet

Deck Mount G1/2 Sensor Faucet Commercial
Overall Height 10 in
Spout Projection 6.2 in
Outlet Height 6 in
Sensor Range 16–32 cm adjustable
Installation Opening 33–35 mm
Plumbing Connection G1/2

The installation drawing places the valve/control enclosure below the basin. Keep the enclosure accessible and avoid locating the waste assembly, carrier, trap or structural framing directly in the service zone.

Fontana FS8033CH AquaDynamiCore chrome touchless faucet dimensional Revit specification reference
PRODUCT ID: FS8033CH

FontanaAquaDynamiCore™ Chrome Touchless Faucet

Single Hole Deck Mount Hot / Cold LED
Overall Height 4.61 in
Faucet Width 2.36 in
Spout Height 3.54 in
Spout Reach 5.87 in
Spout Length 7.48 in
Base Depth 1.65 in

Use the 5.87-inch reach as the primary basin-coordination dimension. Locate the stream within the usable bowl area and verify that the outlet does not direct water toward the rear wall, overflow slot or shallow portion of the basin.

Fontana FS75114BG Bonifacio brushed gold touchless faucet dimensions and single-hole BIM specification
PRODUCT ID: FS75114BG

Fontana Bonifacio Brushed Gold Touchless Faucet

Single Hole Deck Mount Brass Hot / Cold
Overall Height 8.58 in
Width 2.20 in
Spout Reach 7.20 in
Spout Height 7.68 in
Mounting 1-hole deck mount
Valve Ceramic cartridge

The relatively long 7.20-inch spout projection should be modeled with the actual lavatory before countertop fabrication. Coordinate backsplash distance, bowl front-to-back dimension, drain position and splash containment.

Fontana FS10003CP champagne wall mounted touchless faucet BIM rough-in and G1/2 connection reference
PRODUCT ID: FS10003CP

Fontana FlowSphere™ Champagne Wall-Mounted Touchless Faucet

Wall Mount G1/2 AC / DC Brass
Installation Wall mounted
Fixture Opening Single-hole configuration
Inlet G1/2
Outlet G1/2
Power AC / DC
Valve Core Ceramic

Wall-mounted sensor fixtures require coordination before wall closure. Model the finished-wall plane, faucet centerline, basin rim elevation, spout projection, sensor field and accessible service location as one coordinated assembly.

Rough-In, Mounting and Service Clearance Coordination

Coordinate visible faucet geometry together with the concealed plumbing, sensor and power components before countertops, casework or wall finishes are released.

Deck Opening

Do not assume all touchless faucets use the same drilling diameter. Where the manufacturer publishes a specific opening, transfer that dimension to countertop fabrication documents and shop drawings.

Countertop Thickness

Check stone, solid-surface material, substrate and reinforcement against the usable threaded mounting length. FB085-family and FS-9539B installation information shows a nominal maximum countertop thickness of approximately 35 mm.

Control Box Access

Preserve an accessible under-lavatory location for the solenoid, controller, batteries or transformer connection. Do not conceal serviceable components behind fixed millwork.

Water Connections

Verify connection size before branch piping release. Several Fontana sensor faucet systems shown here use G1/2 connections; the approved project submittal governs final connection details.

Sensor Clearance

Keep the intended detection field free of basin edges, reflective backsplashes and accessories that may interfere with activation. FS-9539B publishes an adjustable 16–32 cm detection zone.

Basin Alignment

Model spout reach against the actual basin. The discharge centerline should fall within the functional bowl area while maintaining adequate separation from the rear wall and rim.

Under-Counter BIM Coordination Zone

Elements that should be modeled or reserved when coordinating a commercial sensor faucet installation.

Component BIM / Drawing Requirement Clearance Consideration
Faucet Shank Show deck penetration and required mounting hardware zone. Keep clear of basin flange, clips and structural framing.
Sensor Cable Provide continuous path from faucet to controller. Avoid sharp bends and conflicts with drawer hardware or waste.
Flexible Water Hose Coordinate hose path from faucet / valve to supply. Maintain routing without kinks or trap conflicts.
Control / Solenoid Box Include equipment footprint within the BIM service zone. Front cover and fasteners must remain accessible.
Power Coordinate AC transformer, hardwire or DC battery option. Maintain code-compliant electrical separation and access.
Mixing Valve Model where provided or required by project design. Leave adjustment, isolation and service points accessible.
P-Trap / Waste Coordinate with faucet equipment in section and elevation. Prevent overlap with controller, sensor cable and supplies.

Recommended Revit Family and Fixture-Schedule Parameters

Keep the model useful beyond visual representation by carrying the project data needed by architecture, plumbing and facilities.

Read More: BIM Parameter Checklist
Parameter Recommended BIM Data
Manufacturer FontanaShowers® / applicable product brand
Model Exact product ID / SKU
Description Commercial touchless lavatory faucet
Mounting Type Deck mounted or wall mounted
Spout Reach Model-specific manufacturer dimension
Spout Height Model-specific manufacturer dimension
Connection G1/2 or model-specific connection
Power AC / DC / battery configuration as selected
Flow Rate Project-selected aerator / rated flow
Sensor Range Published or commissioned detection range
Finish Exact scheduled finish
Control Box Dimensions and service-access zone where applicable
Installation Document Link to current model-specific installation PDF
BIM Source Link to current manufacturer BIM / Revit object

Specification and Submittal Workflow

Recommended sequence for carrying the selected Fontana fixture from design development through field installation.

Stage Required Verification AEC Output
Design Development Select exact SKU, mounting type, finish, basin and power strategy. Revit family + preliminary fixture schedule.
MEP Coordination Verify supply, mixing, power, solenoid, controller and waste conflicts. Coordinated plumbing and electrical model.
Countertop Release Confirm faucet-hole diameter, spout centerline and deck thickness. Approved countertop / millwork shop drawing.
Submittal Confirm model, finish, dimensions, flow, connections and accessories. Product data + installation guide + BIM reference.
Installation Compare field conditions with the current manufacturer document. Installed and accessible fixture assembly.
Commissioning Test activation, shutoff, sensor zone, temperature and stream position. Accepted operational fixture.

Use the Exact Product ID in Every BIM and Specification Package

Fontana BIM coordination should begin with the exact scheduled model, not a generic faucet object. Carry the product ID through the Revit family, plumbing fixture schedule, specification, countertop shop drawings, submittal package and closeout documentation so dimensions, mounting, connections, finish and service requirements remain aligned.

Before construction release, confirm the current BIM/Revit object, approved manufacturer submittal and model-specific installation instructions for the selected fixture.

About the Author

Tobias Crane

Hospitality & Environmental Design Specialist

Internationally recognized architect, and design thought leader known for advancing human-centered, socially responsive architecture. His work explores the intersection of architectural innovation, commercial and institutional environments, sustainability, material performance, and practical design. Through research, education, and built projects, he brings a disciplined approach to creating spaces that balance functionality, long-term value, environmental responsibility, and meaningful human experience.